NEMA 14-50, circuito 50 A

Official Tesla technical reference for installing a NEMA 14-50 receptacle for electric vehicle charging using the Tesla Mobile Connector.

This document provides electrical specifications, recommended wiring, circuit breaker requirements, receptacle selection, installation location, and permitting considerations.

Technical Specifications:

  • Voltage: 208–250V AC, single-phase, 60 Hz.

  • Circuit Breaker: 50A.

  • Maximum Continuous Current: 40A.

  • Recommended Wiring: 6 AWG copper.

  • Receptacle: Industrial-grade NEMA 14-50.

  • Installation Height: Minimum 18 inches above ground.

  • Recommended Distance: Within 15 feet of the vehicle charging port.

Document Type: Manufacturer Technical Installation Reference
Manufacturer: Tesla
Publication: November 2014, Version 1.0
Access: Internal – Kaylon Services Technical Knowledge Base

PDF Reference: Mobile Connector

Important: This is a historical Tesla reference. All installations must comply with the currently adopted NEC, applicable local electrical codes, GFCI requirements, manufacturer instructions for the actual charging equipment, and local permitting regulations. The document's original statement that GFCI protection is not required must not be used as current installation guidance.